- .NET 8 SDK.
- Windows for WPF applications and the current raw-Ethernet transport.
- An isolated laboratory or approved commissioning network for active control or process-bus publishing.
git clone https://github.com/masarray/ARIEC61850.git
cd ARIEC61850
dotnet restore .\ARIEC61850.sln
dotnet build .\ARIEC61850.sln -c Release
dotnet test .\ARIEC61850.sln -c Release --no-build
.\scripts\verify-source-clean.cmdInspect the included synthetic SCL model:
dotnet run --project .\apps\AR.Iec61850.Cli -- inspect-scl .\samples\scl\minimal-station.scdGenerate and inspect a deterministic PCAP:
dotnet run --project .\apps\AR.Iec61850.Cli -- generate-pcap .\samples\scl\minimal-station.scd .\.artifacts\out\processbus-demo.pcap
dotnet run --project .\apps\AR.Iec61850.Cli -- inspect-pcap .\.artifacts\out\processbus-demo.pcap --scl .\samples\scl\minimal-station.scdGenerated output belongs under .artifacts/ or another ignored local folder.
Use a documentation-only address in examples and replace it with an approved laboratory endpoint:
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-discover 192.0.2.10 --port 102 --timeout-ms 30000Build the live model directory:
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-directory 192.0.2.10 --port 102 --timeout-ms 30000 --show-points --raw-limit 40Resolve and read a point without manually entering its Functional Constraint:
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-resolve 192.0.2.10 IED1LD0/MMXU1.PhV.phsA.cVal.mag.f
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-read-smart 192.0.2.10 IED1LD0/MMXU1.PhV.phsA.cVal.mag.fThese discovery and read commands are read-only.
Plan report use before changing an RCB:
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-report-plan 192.0.2.10 --port 102 --timeout-ms 60000 --max-report-probes 64 --only-safeRun a guarded report monitor only against an approved test endpoint:
dotnet run --project .\apps\AR.Iec61850.Cli -- mms-report-monitor 192.0.2.10 --port 102 --timeout-ms 120000 --rcb IED1LD0/LLN0.RP.rpt01 --duration-sec 60 --evidence .\.artifacts\out\report-session01 --yesThe monitor may write report-control attributes. Review the plan, target, reservation state, cleanup behavior, and evidence before execution.
IED discovery, reporting, and guarded control:
dotnet run --project .\apps\AR.Iec61850.IedDiscovery -c ReleaseRead-only engineering analysis:
dotnet run --project .\apps\AR.Iec61850.EngineeringWorkbench -c ReleaseLaboratory MMS simulator:
dotnet run --project .\apps\AR.Iec61850.IedSimulator -c ReleaseSampled Values laboratory publisher:
dotnet run --project .\apps\AR.Iec61850.SvPublisher -c ReleaseStart the CLI simulator on loopback:
dotnet run --project .\apps\AR.Iec61850.Cli -c Release -- simulate-ied --port 102 --duration-sec 600From another elevated shell when required by Windows port policy:
dotnet run --project .\apps\AR.Iec61850.Cli -c Release -- mms-discover 127.0.0.1 --port 102 --timeout-ms 30000 --no-report-probeThe simulator currently supports deterministic laboratory discovery and read workflows. It is not presented as a production IED or formal conformance reference.
List adapters:
dotnet run --project .\apps\AR.Iec61850.Cli -- list-adaptersRun bounded dry runs before any active publishing:
dotnet run --project .\apps\AR.Iec61850.Cli -- publish-goose-live .\samples\scl\minimal-station.scd --adapter 1 --stream-index 1 --frames 4 --dry-run
dotnet run --project .\apps\AR.Iec61850.Cli -- publish-sv-live .\samples\scl\minimal-station.scd --adapter 1 --stream-index 1 --frames 4000 --dry-runDo not publish on an operational network without authority, an approved plan, isolation, and independent verification.
- Use synthetic or contributor-owned samples.
- Do not commit customer SCL, live captures, station names, serial numbers, credentials, or internal paths.
- Store generated output under
.artifacts/. - Run
scripts/verify-source-clean.cmdbefore every public push.
For current capability and claim boundaries, see Engine Maturity Matrix. For future work, see Roadmap.