All notable public changes to ARIEC61850 are recorded here. The project is still evolving toward stable semantic releases; entries are grouped by engineering milestone until a formal versioning policy is adopted.
- Added bounded SCL-assisted association resolution for incomplete ConnectedAP addressing: explicit valid selectors/application identity remain immutable constraints, genuinely unspecified fields may be resolved from engine-owned interoperability profiles, malformed/conflicting declarations fail closed, and accepted candidate provenance is retained without mutating the source SCL.
- Added zero-traffic smart-discovery KPI evidence across structural
GetNameList, DataSet directory, hierarchy GVA, and bounded FC-root initial Read phases, including per-phase latency, duplicate semantic-request detection, peak outstanding requests, canonical completeness counters, deterministic repeat-run signatures, and explicit partial wire-accounting status for unobserved enrichment paths. - Added live-authoritative SCL ReportControl family reconciliation for static reporting: indexed declarative controls are matched only to concrete live MMS RCB instances in the same domain/logical-node/report-FC with decimal instance suffixes, while non-indexed controls remain exact-name only and no runtime RCB name is synthesized.
- Added an SCL-aware static report planner that scopes the existing safe RCB selector to the reconciled live family, allowing a busy first instance to fall through to another proven-free instance without escaping to an unrelated control block.
- Added registered-monitor initial GI bootstrap for persistent reporting: the monitor is installed before the one-shot GI request, initial mapped DataSet reports are returned explicitly, and GI is attempted only when the live RCB attribute inventory proves the field exists.
- Added synthetic Edition 1 / Edition 2 static-report family regressions modeled from field evidence, including BRCB
Buffer, URCBUnbuffer, indexed live siblings, explicit URCB reservation planning, and fail-closed behavior when no concrete live family instance exists. - Added a field-trial gate for BRCB/URCB initial-GI qualification, same-family contention, cleanup, and negative/fail-closed cases.
- Added the shared Step-4 initial FC-root Read path for both live-discovery and SCL-assisted workflows: ordered
LN$FCtargets are batched at no more than 10 MMS variables per Confirmed-Read, executed strictly one request at a time, decoded as ordered per-target AccessResults, and projected back to SCL leaves only when nested structure cardinality is exact. - Added opt-in SCL-assisted live MMS association and domain-only validation: an exact typed COTP/ACSE plan can now open one MMS association, query only
GetNameList(Domain,VMD), reconcile expected SCL logical-device domains against live evidence, preserve extra online domains diagnostically, and keep full discovery/write/control/report behavior out of this path. - Added typed, side-effect-free SCL-assisted MMS association planning: ConnectedAP addressing can now be converted into parameterized COTP and ISO Session/Presentation/ACSE/MMS Initiate request bytes with explicit local/calling identity, fail-closed remote/called validation, and golden-byte compatibility coverage; live runtime selection remains a later step.
- Added a typed hybrid report acquisition planner that can cover requested signals with safe static BRCB/URCB plans, use explicitly free dynamic report slots for residual signals, and leave only the remaining points on MMS polling fallback without equating fallback with absence.
- Added the G2.6 production dynamic-report consumer: an optional typed production-planning context can authorize automatic dynamic planning only from an identity-compatible
ProductionEligibleprofile, with exact proven InformationReport RCB/member scope and fail-closed fallback for unproven points. - Added typed IEC 61850 UTC-Time forensic evidence with exact preserved 8-byte wire provenance, the original 24-bit fractional-second field, TimeQuality/accuracy decoding, and explicit full/engineering UTC and local-offset views.
- Added report timestamp evidence that keeps IED data timestamps, report
TimeOfEntry, and clientReceivedAtas distinct evidence sources; rawTimeOfEntryprovenance is linked only when an exact decoded-report match exists.
- Defined the preferred interactive-client report startup as live RCB/DataSet discovery -> SCL-family reconciliation -> safe concrete RCB selection ->
RptEna=true-> persistent routing registration -> one-shot GI -> initial DataSet values -> event-driven monitoring. - Native MMS discovery can now carry bounded, ordered DataSet-directory results in its typed result, allowing live-model, engineering-profile, and readiness builders to consume the same member evidence without application-side reconstruction.
- Hybrid dynamic reporting can host a temporary DataSet in a verified-free RCB Logical Device while its members reference live points in other Logical Devices, matching the MMS named-variable-list model used by Siemens auxiliary RCB pools.
- Production automatic dynamic planning remains P6.2-B quarantined for callers without a valid production context; even when authorized, the first G2.6 consumer is limited to the exact report-proven RCB, report-proven members, one dynamic group, and fresh live availability.
- Preserved full seven-digit UTC-Time precision through the shared MMS scalar/structured renderer and retained exact decoded UTC-Time bytes for byte-exact re-encoding; synthetic UTC-Time values remain explicitly without wire provenance.
- Corrected website structured-data licensing to
GPL-3.0-or-later. - Replaced stale active-license wording and milestone journals with current evidence and future-only roadmap documents.
- Standardized copyright identity as Ari Sulistiono, GitHub account
masarray. - Clarified the Contributor License Agreement parties, grant, and acceptance record.
- Aligned clean-room, contribution, security, operational-risk, and branding policies.
- Replaced broad safety and certification-sounding language with scoped protocol guardrails and evidence boundaries.
- Added automated checks for known stale public wording.
- Updated documentation to reflect persistent report monitoring and the current read-only simulator path.
- SCL-assisted connection no longer rejects a usable CID/SCL before TCP solely because AP-title or AE-qualifier is omitted; the runtime now performs serial fresh-transport negotiation over the bounded engine candidate set and still limits live validation to VMD Domain inventory rather than falling back to full discovery.
- Closed the persistent-monitor GI startup race in the new bootstrap path: a fast IED can no longer deliver the initial GI InformationReport before the target persistent monitor has been registered for routing.
- Hardened the SCL-assisted Step-3 runtime so the configured timeout bounds TCP/COTP/ACSE/MMS plus Domain/VMD inventory, MMS domain identifiers are reconciled case-sensitively, and malformed SCL returns typed validation evidence instead of leaking XML parser exceptions.
- Live-model discovery no longer drops DataSet members when callers request DataSet-directory reads through
MmsClientSession.DiscoverAsync. - Dynamic hybrid planning no longer rejects a verified-free RCB solely because the RCB and requested signal belong to different MMS domains.
- Typed IEC 61850 client-side control-object service in
AR.Iec61850.Control. - Automatic detection and execution of Direct Operate and Select-Before-Operate, normal and enhanced security models.
- Typed live
ctlValbinding for DPC, SPC, INC/ISC, BSC, APC, and validated raw implementation variants. - Immutable sequence handling for
ctlNum,T, origin, Test, interlock check, and synchrocheck. - CommandTermination, LastApplError, ControlError, and AddCause decoding.
- SBO ownership, timeout, best-effort Cancel, association-loss cleanup, and concurrency guards.
- Guarded WPF control tester with OPEN/CLOSE intent, live status feedback, advanced origin/check settings, live-command arming, and command evidence.
- Laboratory IED validation record for one end-to-end control request path.
- Dedicated control-workflow website page and refreshed search/social metadata.
- Repositioned the public README around the core IEC 61850 engineering use cases rather than internal milestone notes.
- Moved detailed capability history to documentation and changelog files.
- Improved GitHub Pages information architecture, accessibility, mobile layout, and technical metadata.
- Updated documentation navigation and public validation boundaries.
- Missing
System.IOnamespace in the WPF control tester. - Expired SBO selection state returning
Rejectedinstead of deterministicTimedOut. - xUnit analyzer findings for collection assertions.
- Duplicate milestone sections in the previous README.
Earlier milestones include MMS association and discovery, reporting readiness and persistent monitoring, GOOSE and Sampled Values codecs and diagnostics, SCL engineering profiles, PCAP workflows, deterministic simulation, Windows raw-Ethernet transport, Sampled Values laboratory publishing, and engineering evidence export.
See Engine Maturity Matrix for current evidence and Roadmap for future work.